Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Spec Oper Med ; 2024 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-38423001

RESUMO

BACKGROUND: Recommendations for optimal temperature and humidity for sterile instrument storage vary according to different sources. Furthermore, there are limited data comparing methods of packing smaller, lightweight, low-profile instruments. The purpose of this study was to compare sterile peel packaging and sterile cellulose wrapping for sterile instrument storage in an austere environment characterized by elevated temperature and humidity. METHODS: Stainless steel screws were sterilized and stored in either sterile peel packaging, sterile cellulose wrapping, or no packaging. Four groups were evaluated. Group 1 consisted of four screws in a sterile peelpack envelope and served as a time-zero control. Group 2 consisted of two groups of five screws, each packaged with blue sterilization cellulose wrap. Group 3 consisted of two groups of five screws, each packaged in sterile peel-pack envelopes. Group 4 consisted of 10 non-sterile unpackaged screws, which served as controls. Screws from groups 2, 3, and 4 were then cultured for 6 and 12 weeks. Temperature and humidity values were recorded in the instrument storage area. RESULTS: Average temperature was 21.3°C (SD 1.2°C; range 18.9°C-27.2°C) and average humidity was 51.7% (SD 3.9%; range 39%- 70%). Groups 1 (time-zero control) and 2 (sterile cellulose wrapping) demonstrated no growth. After 6 and 12 weeks, groups 3 (sterile peel packaging) and 4 (control) demonstrated bacterial growth. CONCLUSION: The most common culture isolates were gram-positive rods and two common nosocomial Staphylococcius species. Sterile peel packaging was not found to be equivalent to sterile cellulose wrapping in austere environmental conditions.

2.
Tech Hand Up Extrem Surg ; 28(1): 39-44, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-37899629

RESUMO

Elbow arthroscopy is an important surgical technique for the treatment of various elbow pathologies. Range of indications for elbow arthroscopy include, but are not limited to, diagnostic evaluation, removal of loose bodies, synovectomy, contracture releases, lateral epicondylitis treatment, and adjunct use for fracture reduction. Surgeons' understanding of anatomy and portal placement is critical for successful treatment. This article reviews the relevant surgical anatomy, portal placement, patient positioning, surgical indications, and complications for this technique.


Assuntos
Articulação do Cotovelo , Cirurgiões , Cotovelo de Tenista , Humanos , Artroscopia/métodos , Cotovelo/cirurgia , Articulação do Cotovelo/cirurgia , Cotovelo de Tenista/cirurgia
3.
JBJS Case Connect ; 13(3)2023 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-37437047

RESUMO

CASE: We present a case of a 21-year-old male patient with a symptomatic os acromiale treated with open reduction internal fixation with distal clavicle autograft. The patient presented with right shoulder pain after a motor vehicle accident with tenderness over the acromion. Radiographs demonstrated an os meso-acromion with corresponding edema on Magnetic Resonance Imaging (MRI). The patient recovered uneventfully with radiographic fusion at 8 months of the os acromiale site. CONCLUSION: This case used the excised distal clavicle as autograft. This technique has the added advantage of harvesting autograft from the same surgical approach and potential mechanical advantage of offloading the os acromiale site to promote healing.


Assuntos
Acrômio , Clavícula , Masculino , Humanos , Adulto Jovem , Adulto , Clavícula/diagnóstico por imagem , Clavícula/cirurgia , Autoenxertos , Transplante Autólogo , Acrômio/diagnóstico por imagem , Acrômio/cirurgia , Acidentes de Trânsito
4.
J Hand Surg Am ; 48(2): 149-157, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-35870956

RESUMO

PURPOSE: We examined morphologic similarities of the medial lateral femoral trochlea (MFT) and lateral femoral trochlea (LFT) osteochondral flaps for reconstruction of the proximal capitate. METHODS: Magnetic resonance imaging scans of the wrists and ipsilateral knees of 10 young healthy volunteers were obtained. Three morphologic parameters were investigated, comparing the MFT and LFT harvest sites to the capitate proximal pole. The correspondingly relevant surgical planes were compared. The coronal plane radius of curvature (ROC) of the capitate was compared with the sagittal planes of the MFT and LFT. The sagittal plane ROC of the capitate was compared to the axial planes of the MFT and LFT. The angular relationship between the dorsal cortical surface of the capitate and the proximal pole cartilage (proximal dorsal capitate pitch) was compared to the corresponding angles between the cortical bone and convex cartilage on the LFT and MFT. RESULTS: The average ratios of ROC for the coronal planes of the capitate to the MFT (0.61) and LFT (0.58) were similar. The average ratios of ROC for the sagittal planes of the capitate to the MFT (0.57) and LFT (0.86) were also similar. The proximal dorsal capitate pitch demonstrated greater similarity to the corresponding shape of the LFT (angular ratio, 1.01) than to that of the MFT (angular ratio, 0.74). CONCLUSIONS: The LFT and MFT demonstrate similar congruity to the proximal capitate in the sagittal and coronal planes of the wrist. The LFT dorsal pitch closely approximates the relationship of the proximal capitate pole to its dorsal cortical surface. CLINICAL RELEVANCE: In capitate fracture, fracture nonunion, or avascular necrosis, both the MFT and LFT demonstrate similarity to the proximal convex capitate morphology. The relationship between the cortical and chondral surfaces of the LFT is morphologically very similar to that of the proximal capitate.


Assuntos
Capitato , Osteonecrose , Humanos , Retalhos Cirúrgicos/irrigação sanguínea , Capitato/diagnóstico por imagem , Capitato/cirurgia , Punho , Cartilagem , Osteonecrose/cirurgia
5.
J Hand Surg Am ; 48(12): 1276.e1-1276.e7, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-35778231

RESUMO

PURPOSE: We compared 2 suturing techniques for reattachment of the flexor digitorum profundus (FDP) via all-suture anchor. METHODS: We used fresh, matched-pair, cadaveric hands. We disarticulated the fingers at the proximal interphalangeal joints, preserving the proximal FDP. We released the FDPs at their distal insertion and placed an all-suture, 1.0-mm anchor at the center of each FDP footprint. Each anchor's sutures were used to reattach each FDP using 1 of 2 techniques: group H (n = 14) via horizontal mattress; group H + K (n = 12) via horizontal mattress with knots thrown and, with each suture tail, 3 proximal, running-locking, Krackow-type passes on the radial and ulnar FDP sides with the suture ends tied together. We excluded 2 specimens from the H + K group because of improper anchor placement. All other fingers in both groups were individually mounted in an MTS machine for FDP loading in the following sequence for 500 cycles each: (1) to 15 N to simulate passive motion forces; (2) to 19 N for short-arc active motion forces; and (3) to 28 N for full active motion forces. Specimens that had not failed during cyclic testing were then loaded to failure. We measured FDP-to-bone gapping via a digital transducer. We defined failure as >3-mm gapping. RESULTS: The H + K group had significantly less gapping during cyclic loading up to 19 N and significantly higher load to failure. The H + K group failed exclusively at the anchor-bone level; the H group failed mostly by suture-tendon pullout. CONCLUSIONS: The H + K group performed significantly better regarding cyclic and load-to-failure testing after FDP reattachment. CLINICAL RELEVANCE: The H + K technique combines the benefits of horizontal-mattress tendon-to-bone apposition and Krackow-tendon locking. It converts the point of failure to the bone level rather than the suture-tendon level.


Assuntos
Traumatismos dos Dedos , Traumatismos dos Tendões , Humanos , Âncoras de Sutura , Traumatismos dos Tendões/cirurgia , Traumatismos dos Dedos/cirurgia , Tendões/cirurgia , Técnicas de Sutura , Fenômenos Biomecânicos , Cadáver
6.
Mil Med ; 187(1-2): e11-e16, 2022 01 04.
Artigo em Inglês | MEDLINE | ID: mdl-33231690

RESUMO

INTRODUCTION: Positioning of implant components for total hip arthroplasty (THA) is important for polyethylene liner wear, prosthesis joint stability, and range of motion. The introduction of fluoroscopy for the direct anterior approach has been shown to improve physician accuracy for component positioning. Few studies compare the use of intraoperative fluoroscopy for THA component positioning in posterior THA. The purpose of this project is to retrospectively evaluate the effect of intraoperative fluoroscopy on component positioning for THA using posterior and direct anterior approach (DAA). MATERIALS AND METHODS: A retrospective review of postoperative weight-bearing X-ray films of THAs was performed over a 2-year period where a single fellowship-trained total joint surgeon introduced direct anterior approach into his practice while expanding the intraoperative use of fluoroscopy for all THA procedures, regardless of approach. Component position was evaluated through radiographic measurement of acetabular cup inclination (goal of 40 degrees), limb length discrepancy (goal of 0 mm), and femoral component offset difference (goal of 0 mm). Radiographic analysis was performed by two independent providers. Statistical analysis was performed using Student's t-tests. RESULTS: A total of 107 patients with an average age of 62 years were identified during the 2-year period surrounding the THA practice change, adding fluoroscopy to posterior and DAA THA. Three cohorts were identified: cohort A: 44 patients who underwent posterior THAs without the use of intraoperative fluoroscopy, cohort B: 35 patients who underwent direct anterior approach THAs with the use of intraoperative fluoroscopy, and cohort C: 18 patients who underwent posterior THAs with the use of intraoperative fluoroscopy. The use of intraoperative fluoroscopy for the posterior approach versus unguided posterior approach increased accuracy of both cup inclination (44 degrees vs 50 degrees, P < .05) and femoral offset (4 mm vs 7 mm, P < .05). A comparison of DAA with fluoroscopy versus posterior approach without fluoroscopy showed improvement in cup inclination (48 degrees vs 50 degrees, P < .05). Fluoroscopy with posterior approach versus fluoroscopy with DAA was found to have improved cup inclination (44 degrees vs 48 degrees, P < .05). CONCLUSION: Intraoperative use of fluoroscopy can improve component positioning for posterior THA.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Acetábulo/cirurgia , Artroplastia de Quadril/efeitos adversos , Fluoroscopia/métodos , Articulação do Quadril/cirurgia , Humanos , Pessoa de Meia-Idade , Estudos Retrospectivos
7.
JBJS Rev ; 9(4)2021 04 05.
Artigo em Inglês | MEDLINE | ID: mdl-33819199

RESUMO

¼: Surfing is safe: the risk of injury ranges from 0.26 to 0.90 injuries per surfer per year, 0.06 to 3.5 injuries per 1,000 days of surfing, and 1.1 to 13.0 injuries per 1,000 hours of surfing. ¼: The most common acute surfing injuries are lacerations, contusions, and sprains; the head and the neck as well as the lower extremities are the locations that are affected most. ¼: The most common mechanism of injury is striking a surfer's own board or that of another surfer. ¼: A pathology that is unique to surfers is surfer's myelopathy; bites and/or stings by sea life and infections caused by marine life also occur in surfers.


Assuntos
Traumatismos em Atletas , Cirurgiões Ortopédicos , Doenças da Medula Espinal , Esportes , Entorses e Distensões , Traumatismos em Atletas/complicações , Traumatismos em Atletas/cirurgia , Humanos , Doenças da Medula Espinal/etiologia , Entorses e Distensões/complicações
8.
Artigo em Inglês | MEDLINE | ID: mdl-32656481

RESUMO

Vascularized medial femoral condyle bone grafts have been reported to be a reliable treatment for recalcitrant bony nonunions of the extremities. Although clavicle fracture nonunions are rare after treatment with open reduction internal fixation, symptomatic nonunions can be a challenge. The medial femoral condyle vascularized bone graft has been described as a treatment option for clavicle nonunions with the thoracoacromial trunk as the recipient anastomosis site. This case illustrates how the transverse cervical artery and accompanying veins can be used as an anastomosis when the thoracoacromial trunk is inaccessible because of previous surgical- and infection-related scaring. At the final follow-up, the patient had returned to full duty and resumed competitive triathlons. Radiographs demonstrated complete healing of clavicle fracture.


Assuntos
Clavícula , Fraturas não Consolidadas , Anastomose Cirúrgica , Artérias , Clavícula/diagnóstico por imagem , Fraturas não Consolidadas/diagnóstico por imagem , Humanos , Estudos Retrospectivos
9.
J Pediatr Orthop ; 40(3): e222-e226, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31386642

RESUMO

BACKGROUND: Multiple hereditary exostosis is a benign condition that can lead to significant forearm deformity secondary to physeal disturbances. As the child grows, the deformity can worsen as relative shortening of the ulna causes tethering, which may lead to increased radial articular angle, carpal slippage, and radial bowing, over time this tethering can also result in radial head subluxation or frank dislocation. Worsening of forearm deformities often require corrective reconstructive osteotomies to improve anatomic alignment and function. The purpose of this study is to evaluate the effectiveness of osteochondroma excision and distal ulnar tether release on clinical function, radiographic anatomic forearm alignment, and need for future corrective osteotomies. METHODS: The authors reviewed a retrospective cohort of preadolescent patients who underwent distal ulna osteochondroma resection and ulnar tethering release (triangular fibrocartilage complex). Patients were invited back and prospectively evaluated for postoperative range of motion, pain scores, self-reported and parent-reported Disabilities of the Arm, Shoulder, and Hand (DASH) and Pediatric Outcomes Data Collection Instrument (PODCI) scores. In addition, preoperative and final postsurgical follow-up forearm x-rays were reviewed. RESULTS: A total of 6 patients and 7 forearms were included in our study with an average age of 7.9 years at time of surgery. The average final follow-up was 7.4 years. With respect to range of motion, only passive radial deviation demonstrated improvement -20 to 14 degrees (P=0.01). Although there was not statistically significant change in radial articular angle, this study did find an improvement in carpal slip 75.7% to 53.8% (P=0.03). At final follow-up DASH score was 5.71 (σ=5.35), PODCI Global Function score was 95.2 (σ=5.81), and PODCI-Happiness score 98 (σ=2.74). Visual analogue scale appearance and visual analogue scale pain assessment were 1.67 (σ=1.21) and 1.00 (σ=1.26), respectively, at final follow-up. No patient in the cohort developed a radial head dislocation. Only one of 7 forearms required a corrective osteotomy within the study's follow-up time period. CONCLUSIONS: Surgical excision of forearm osteochondromas with ulnar tether release in the preadolescent patients improves carpal slip, may help to prevent subsequent surgical reconstruction and provides satisfactory clinical results at an average 7-year follow-up. LEVEL OF EVIDENCE: Level III-therapeutic study.


Assuntos
Neoplasias Ósseas , Exostose Múltipla Hereditária/complicações , Antebraço , Deformidades Adquiridas da Mão , Osteocondroma , Osteotomia/métodos , Neoplasias Ósseas/etiologia , Neoplasias Ósseas/cirurgia , Criança , Feminino , Antebraço/patologia , Antebraço/fisiopatologia , Deformidades Adquiridas da Mão/diagnóstico , Deformidades Adquiridas da Mão/etiologia , Deformidades Adquiridas da Mão/cirurgia , Humanos , Masculino , Osteocondroma/etiologia , Osteocondroma/cirurgia , Radiografia/métodos , Estudos Retrospectivos , Resultado do Tratamento , Ulna/patologia , Ulna/cirurgia
10.
Orthopedics ; 43(2): e91-e94, 2020 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-31841605

RESUMO

The Achilles tendon is a common site of anatomical injury among athletes and those participating in recreational sporting activities. Acute Achilles tendon ruptures are often misdiagnosed as a sprained ankle and are more common in the male population. Mechanism of injury is often a noncontact injury, resulting from sudden forced plantar flexion or violent dorsiflexion in a plantar flexed foot. Delays in diagnosis and treatment may complicate the clinical outcome. Because findings may be subtle on history and physical examination, the use of readily available adjunctive studies is important for practitioners. One method is the analysis of Kager's triangle on lateral ankle radiographs. Obscuration of Kager's triangle has been described as a radiographic indicator of Achilles tendon rupture, but the sensitivity and specificity of this finding have been poorly reported. [Orthopedics. 2020; 43(2): e91-e94.].


Assuntos
Tendão do Calcâneo/lesões , Pontos de Referência Anatômicos , Articulação do Tornozelo/diagnóstico por imagem , Ruptura/diagnóstico , Traumatismos dos Tendões/diagnóstico , Tendão do Calcâneo/diagnóstico por imagem , Estudos de Coortes , Humanos , Radiografia , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
11.
J Hand Surg Am ; 42(2): e115-e117, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27889093

RESUMO

Subdermal implantable devices are commonly used for long-acting contraception in the United States and Europe. Although relatively safe in nature, their implantation and removal may be associated with potential complications, some of which may require surgical intervention. Complications may include infection, incorrect implantation, migration, or difficulty with removal. Proximal migration has been reported; however, there are no reports of devices that have migrated within the brachial neurovascular sheath. This case report describes migration of an implantable contraceptive within the brachial neurovascular sheath that required surgical removal.


Assuntos
Braço , Anticoncepcionais Femininos , Remoção de Dispositivo , Implantes de Medicamento/efeitos adversos , Migração de Corpo Estranho/cirurgia , Adulto , Feminino , Fluoroscopia , Migração de Corpo Estranho/diagnóstico por imagem , Humanos
12.
Hand (N Y) ; 10(2): 297-300, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26034447

RESUMO

BACKGROUND: Open trigger finger release is generally considered a simple low-risk procedure. Reported complication rates vary widely from 1 to 43 %, mostly based on small studies. Our goal was to determine the incidence of complications in a large consecutive series, while also identifying potential risk factors. METHODS: All open trigger finger releases performed from 2006 to 2009 by four fellowship-trained hand surgeons at a single institution were retrospectively reviewed. There were 795 digits released in 543 patients. Complications were defined as signs or symptoms requiring further treatment and/or considered unresolved by 1 month postoperatively. Complications requiring operative intervention were regarded as major. Multivariable analysis was performed to determine possible risk factors for complications. RESULTS: There were 95 documented complications among 795 digits (12 %). The most common complications involved persistent pain, stiffness, or swelling, persistent or recurrent triggering, or superficial infection. Most were treated nonoperatively with observation, therapy, steroid injection, or oral antibiotics. There were 19 reoperations (2.4 %), mostly including revision release, tenosynovectomy, and irrigation and debridement. Male gender, sedation, and general anesthesia were independently associated with complications, while age, diabetes, hypothyroidism, recent injection, and concurrent procedures were not associated. CONCLUSIONS: Open trigger finger release is generally a low-risk procedure, although there is potential for complications, some requiring reoperation. Male gender, sedation, and general anesthesia may be associated with greater risk. Surgeons should be careful to thoroughly discuss the risk of both major and minor complications when counseling patients.

13.
J Nucl Cardiol ; 18(2): 230-7, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21132417

RESUMO

BACKGROUND: The benefit of myocardial perfusion imaging (MPI) over exercise ECG stress testing alone is unclear in individuals attaining a workload of ≥10 METS. The purpose of this prospective study is to determine mortality and nonfatal cardiac events in patients at either intermediate pretest risk for CAD or patients with known CAD, achieving ≥10 METS regardless of peak exercise heart rate. The authors previously reported a low prevalence of significant ischemia in this patient cohort. METHODS: Baseline characteristics, ECG stress test findings, and perfusion and function results from quantitative gated (99m)Tc-SPECT MPI were compared by achievement of a maximum age-predicted heart rate ≥85% in 509 consecutive patients who reached ≥10 METS. Events including all-cause and cardiac mortality, non-fatal myocardial infarction (MI), and late revascularization (>4 weeks after MPI) were prospectively collected. RESULTS: Of the 509 patients achieving ≥10 METS, follow-up for mortality was obtained in 463 (91%). Those lost to follow-up were older and had higher rates of tobacco use. The prevalences of CAD risk factors, prior known CAD, and MPI abnormalities were higher for the 68 patients failing to reach 85% of their target heart rate. The rate of ≥10% left-ventricular (LV) ischemia by MPI remained very low irrespective of attained heart rate (0.6% (3/463)). Six (1.2%) had an LVEF < 40%. Death occurred in 12 (2.6%) patients, one of which was classified as cardiac (0.1%/year). The other 11 deaths were related to cancer. Additionally, there were three nonfatal MIs (0.7 %) and one late revascularization (0.2%). Only one of these patients had any ischemia on MPI. No cardiac event patient had exercise ST depression or ≥5% LV ischemia. CONCLUSIONS: Thus, patients at intermediate risk for CAD or known CAD achieving ≥10 METS have a very low prevalence of ≥10% LV ischemia and very low rates of cardiac mortality, nonfatal MI, and late revascularization, irrespective of heart rate achieved. Cardiac events did not correlate with abnormalities on the index MPI study. These results suggest that patients who attain ≥10 METS during exercise stress have an excellent prognosis over an intermediate term of follow-up, regardless of peak exercise heart rate achieved. The added value of MPI to standard exercise ECG testing in this population is questionable.


Assuntos
Doença da Artéria Coronariana/etiologia , Teste de Esforço , Imagem de Perfusão do Miocárdio , Tomografia Computadorizada de Emissão de Fóton Único , Adulto , Idoso , Doença da Artéria Coronariana/mortalidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...